Home > Jcl Error > Jcl Error Codes

Jcl Error Codes

Contents

Verify that all the volumes which the data set resides on are specified in the sequence in which the data set exists. 3. The file-control select clause was missing for the data set that was being processed. S0E6 - UNABLE TO PROCESS A DATA SET THAT HAS ALREADY BEEN SCRATCHED. The volume serial numbers were specified in wrong sequence. http://wirelessready.org/jcl-error/jcl-error-codes-pdf.html

If a data set is used from a preceding job step, be sure that the data set was created and passed correctly. A JCL DD statement was either invalid or missing. 2. U3690 - SYSTEM SOFTWARE OR DISK PROBLEM OCCURRED DURING THE EXECUTION OF A LINK OR LOAD INSTRUCTION / INSURE THAT THE LOAD REQUEST IN THE PROBLEM WAS SPECIFIED CORRECTLY AND WAS Data is not numeric, but should be.

Jcl Error Codes List Pdf

You might need to increase the amount of primary and secondary space to be allocated for a dataset in the ‘SPACE=’ parameter, or you may have to move the dataset to S013 - D0 - A DB/DBS RECORD FORMAT WAS SPECIFIED FOR QSAM LOCATE MODE, BUT THE LOGICAL RECORD INTERFACE IS NOT PRESENT IN THE ASSOCIATED BUFFER CONTROL BLOCK; IE. use following command to stop command /stop PGB ------------ status codes ------------ GE - End Of Segment AC - Invalid SSA * Invalid Segment name specified in SSA * The Moving data to a zero address or to an address less than 512 (decimal) is a very frequent cause of this abend.

Back to top <-- Click on right mark icon. Incomplete DCB for SORTIN file. AN AUTHORIZED PROGRAM REQUESTED VIRTUAL STORAGE THAT REQUIRES MORE REAL STORAGE THAN IS AVAILABLE. User Abend Codes In Mainframe Run the program again.

S002 - 28 - THE ERROR OCCURRED DURING THE CREATION OF A DIRECT DATASET. You are trying to access a dataset which you are not authorized to use. 1. Writing a tapemark. 3. http://mainframe-wiki.blogspot.com/2011/07/jcl-error-codes-and-abends.html S722 The maximum number or output lines has been exceeded. 1.

An error occurred while positioning at the labels, (or if there were no labels, while positioning at the data) of a data set opened with input or inout to be read File Status Codes In Cobol S113 - 20 - END-OF-VOLUME ENCOUNTERED FOR A VSAM DATA SET. S002 - 90 - POINT DETECTED AN ERROR WHILE ATTEMPTING TO CONNECT TO A PDSE MEMBER. An invalid volume sequence number in the JCL specified a value greater than the number of volumes contained on the data set.

Mainframe Abend Codes List Pdf

S013 - D8 - A CONFLICT HAS OCCURRED FOR THE SPANNED RECORD FORMAT EXTENDED LOGICAL RECORD INTERFACE (XLRI). http://ruifeio.com/2011/12/03/most-common-jcl-error-codes/ Check the adapter. -+Z_588 Message = Unable to initialize token-ring adapter. Jcl Error Codes List Pdf Recreate the data set specifying the correct DCB information. 3. Common Jcl Errors If a TSO session times     out you will probably get an S522 abend code.

S813 The data set name in the JCL did not match the data set name on the tape. 1. navigate here SEGMENT MODE IS IMPLIED. The quotient exceeded the allowed data field size. 3. SEGMENT MODE IS IMPLIED. Db2 Abend Codes

A reason code in register 15 explains the error: reason code 4 - The program issued TIMEUSED with LINKAGE=SYSTEM, but the program was not in task control block (TCB) mode. There was no more room available to receive any more output on the output volume, and another volume could not be mounted. 1. U0688 IMS not active./ JOB cancelled (JOB ran in the wrong JOB class). http://wirelessready.org/jcl-error/jcl-error-codes-list.html IKJ5555442 NO VALID TSO USERID, DEFAULT USER ATTRIBUTES USED READY%E77441QRY I - > Execution BeginsE - > ..E - > Trying to execute a non - update SQLE - > Check

There was a conflict between the program, the JCL DCB, and the data set DCB information. Jcl Error Cn(internal) Reference to a field in a record before OPEN or after CLOSE. S233 - 38 - THE CALLER SPECIFIED THE 4K SQA BUFFER (BUFFER=YES) BUT AN SVC DUMP WAS ALREADY IN PROGRESS.

The system ends the job.

Tried moving variable length record that was larger than target field size 9. U0778 Blocksize or LRECL problem U0844 Production database out of space. An error occurred in tape positioning following header label processing. 1. Ims Abend Codes S104 - 04 - NOT ENOUGH REAL STORAGE FOR SPACE IN SQA SUBPOOL.

S213 - 40 - WHEN OPENING A PDSE, MACRF=(E) WAS SPECIFIED. THE ITEMS IN THE PROBLEM DETERMINATION AREA OF GREATEST INTEREST TO YOU ARE: (ALL OFFSETS IN HEX)- OFFSET 10 CONTAINS A COPY OF THE REGISTERS WHEN EXCP DETERMINED THE ERROR CONDITION.- S806 A load module requested by the program could not be found. 1. this contact form A disk dataset was not actually on the volume indicated in the catalog.

S0E0 - 31 - AN UNSTACKING INTRUCTION WAS ISSUED WHEN THE LINKAGE STACK HAS NO STACK ENTRIES. S30A - 18 - PRIVATE AREA SUBPOOL NOT FOUND. S002 - 0C - AN INVALID RECORD WAS ENCOUNTERED ON A PUT OR WRITE OPERATION. S30A - 14 - PRIVATE STORAGE IS NOT IN THE SUBPOOL SPECIFIED.

Possible causes: 1. Check whether PDS name given in step lib is spelled correct. 3. SOC1-5     Reading after the end of the file by non-COBOL program.