Home > Jcl Error > Jcl Errors And Abends

Jcl Errors And Abends

Contents

Recreate the problem data set if necessary. You don't see code like this -if ( ( f = fopen(... ) ) == NULL ) printf( "I can't open...\n" );else { .... }in mainline MVS programs, even though many To resolve the issue, specify the output dataset with larger primary and secondary quantity, and re-run the job. S137 - 30 - A LABEL VIOLATED THE PUBLISHED STANDARD FOR THE LABEL, AND THE LABEL VALIDATION EXIT REQUESTED OPEN/EOV TO REJECT THE VOLUME. have a peek here

At end of tape volume. 1. If the record length exceeds the track length, specify a different device in the unit parameter. IF THE REGISTER 15 RETURN CODE IS AVAILABLE, SUPPLY IT IN THE S171 OPERAND FOR MORE SPECIFIC INFORMATION: H ABEND O(S171-RC)POSSIBLE CAUSE:INPUT PARAMETER ERROR IN VIRTUAL SUBAREA LIST (VSL):- VSL NOT use following command to stop command /stop PGB ------------ status codes ------------ GE - End Of Segment AC - Invalid SSA * Invalid Segment name specified in SSA * The http://www.mainframetutorials.com/abends.html

Jcl Error Codes List Pdf

THE CONTROL PROGRAM FOUND AN INVALID EVENT CONTROL BLOCK ADDRESS, OR THE ECB WAS IN A STORAGE AREA WITH A PROTECTION KEY DIFFERENT FROM THAT OF THE TASK ISSUING THE MACRO. DCB mismatch. U0519 Missing GO BACK, EXIT or STOP RUN. S305 - THE ERROR OCCURRED DURING EXECUTION OF A FREEMAIN MACRO:- THE SPECIFIED SUBPOOL COULD NOT BE FOUND.- THE SP PARAMETER WAS SPECIFIED BUT THE VIRTUAL STORAGE AREA TO BE RELEASED

if some body using the psb and you want to stop that transaction. DURING THE EXECUTION OF OPEN IT WAS DETECTED THAT THE BLOCKSIZE WAS LARGER THAN THE PRIMARY EXTENT. There were not enough volumes allocated for the data set. 3. Cobol Error Codes If still you are getting the same SB37, then you need to change the Tracks to Cylinders. 3.

All space was filled on the volume, and an attempt was made to obtain space on the next specified volume. S213 Abend A disk dataset was not actually on the volume stated in the VOL=SER=. sss The step name. http://mainframegeek.me/abend-codes-and-explanation/ S013 - 54 - NO SECONDARY CONTROL UNIT COULD NOT BE FOUND FOR A 1419.

The default is 5, therefore a request for the sixth volume will fail with a E37  S80A  S804  S822 S80A, S804 Region too small for the program to run S822 - S722 Abend POSSIBLE CAUSE - DATASET WAS TO BE WRITTEN ON BUT WAS OPENED AS INPUT- LRECL/BLKSIZE PROBLEM EXISTS - INVALID VALUES OR NOT MULTIPLES S03D - THE ERROR OCCURRED DURING THE EXECUTION Used DD DUMMY with logic that moves high values to FD 10. SOC1-5     Reading after the end of the file by non-COBOL program.

Mainframe Abend Codes List Pdf

A program loop containing an arithmetic instruction caused an invalid result. http://ibmmainframes.com/references/a29.html S12E - ERROR FOUND IN INPUT PARAMETERS TO TTIMER SERVICE ROUTINE. Jcl Error Codes List Pdf S317 - The request cannot be fulfilled by the server Home | Mainframe Wiki | Free Downloads | Sample Programs | More References | Mainframe Forum IBMMainframes.com Quick References Db2 Abend Codes System Programmer Response: If the error recurs and the program is not in error, look at the messages in the job log for more information.

RECFM=F was specified and the logical record length was not the same as the block size. navigate here An ABEND (abnormal end) is just another way to express an error. Check for subscript errors, missing DD card, file not opened.     (Missing / Misspelled DD name, Read / Write to un-opened dataset, Read to dataset that opened in       OUTPUT mode, Mainly SOC7 abend occurs due to invalid digit / sign present at last byte of comp-3 value. User Abend Codes In Mainframe

Numeric data was not initialized, blanks were read into a field designed to be processed with packed decimal instruction. 3. Then do the data correction for that particular record and re-run the job. S0E0 - AN INVALID OR UNRECOGNIZED PROGRAM INTERRRUPT OCCURRED.POSSIBLE CAUSE- THIS LEVEL OF MVS IS NOT THE CORRECT ONE FOR THE HARDWARE, ESPECIALLY IF THE INTERRUPT CODE IS UNKNOWN. Check This Out referencing a field in a record of a closed file referencing an item in Linkage-Section when there was no PARM= in the JCL.

U0474 Maximum time.; Message region stopped - contact data center. Common Jcl Errors S213 - 40 - WHEN OPENING A PDSE, MACRF=(E) WAS SPECIFIED. Search problem reporting data bases for a fix for the problem.

Note: a comp-3 field may not exceed 15 digits.

Unintentional branch to invalid instruction due to subscript error. S002 Abend With variable format files used for output. kaviyarasan Posts: 4Joined: Mon Feb 18, 2008 8:44 am Hasthanked: 0 time Beenthanked: 0 time Top Re: Jcl errors, abends and their remedies by MrSpock » Thu Feb 21, 2008 S413 Abend BUFFER CONTROL BLOCK; IE.

S0E4 - THE ERROR OCCURRED WHILE TRYING TO SCRATCH A VIO DATASET. The block count of the tape label did not agree with that of the DCB. Programs set different Return-codes, to indicate different things to the Outside-world, and raise an alarm. this contact form S0C8   S0C9   S0CA  Decimal point overflow error S0CB  Attempting to divide by 0 and not using ON SIZE ERROR S0CC  Floating Pointing S0CD  Exponent overflow and Underflow execptions S013

In writing to a sequential data set with variable length records, an invalid length field was encountered: 1. S0E0 - 33 - AN INVALID LINKAGE STACK ENTRY (LSE) TYPE WAS ENCOUNTERED BY THE HARDWARE OR BY AN UNSTACKING OPERATION. Make sure your load module is available in the given load lib. 2. Member name if specified.

S0B0 - 20 - INVALID BLOCK POINTER (WRITE LOCATE IS ATTEMPTING TO WRITE AND IS PASSING A BLOCK POINTER WHICH IS NOT VALID FOR THE SVA REQUESTED). S233 - 10 - IN A USER-SUPPLIED STORAGE RANGE, THE START ADDRESS IS GREATER THAN THE END ADDRESS. Generally it can be categorized into system abend and user abend.System Abend - It will occurs when the system is not able to execute a statement which is coded in a Verify that the volume contains standard labels. 3.

THE PICA ADDRESS IS INVALID. Correct any inconsistencies. Provide the SYSOUT output for the job. What prompted the question?The people who encourage the use of proper termnology use "abend" to mean a System (Sxxx) or a User (Unnnn) abend (which causes the 3rd positional parameter of

U0201 FDR - tape End-Of-File before dataset or trailer record found. An attempt was made to output to the data set, before the expiration date specified had been reached. 2.